断线检测器简易说明书
声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!
断线检测器简易说明书
文本预览
专利产品 仿冒必究
断线监测器
Line break monitor
概述 Summarization
The line break monitor is an instrument that detect whether has
断线监测器是监测室外长距离线路是否断线的设备,具 n
outdoor long distance circuitry broken line, has the function of broken
有断线报警及继电器干接点输出功能。 line warning and the relay main contact output.
c
型号 S3-KL-J Model S3-KL-J
Capability indexes .
性能指标
h
Line break indication: when line break occur, the warning
断线指示:当发生断线时,报警指示灯亮,继电器接点
indicator light will light, the relay contact closed.
闭合。
Relay input: normallys open contact,
继电器输出:常开接点,接点容量:DC30V,1A
contact capacity: DC30V, 1A
工作电源:DC24V
Working power. supply: DC24V
整机功耗:<40mA(DC 24V时)
Full poweri supply consumption: <40mA (when DC 24V)
工频耐压:输入/输出、电源/输入之间隔离电压不小于
Power efrequency withstands voltage: the isolation voltage
2KV/1min · 1mA,电源/输出间之间隔离电压
between input/output, power/input no less than 2KV/1min · 1mA,
不小于1KV/1min · 1mA。
wthe isolation voltage between power/output no less than
监测灵敏度:6kΩ
1KV/1min · 1mA.
线路耦合电容:≤0.1uF
Monitor sensitivity: 6kΩ
安装方式: 35mm导轨和盘面镙钉固定两种方式
g Circuitry coupling capacitance: ≤0.1uF
外形尺寸:55mm×75mm×120 mm
Installation mode: 35mm guide apparatus and panel
接线图
n screw fixation
External dimensions: 55mm×75mm×120 mm
INPUT
o Wiring diagram
1 2 3 4
(As left figure shows)
y
5 6 7 8 Special hint: In order to insure the
equipment safety, the second terminal of the
.+ -
OUTP wUT 24V monitor should be grounding well.
Notice
特别提示:为确保设备安全,断
线监测器②号端子必须良好接地。 The input line which connects ① and ③ position must be
w
注意事项 parallel connection into monitored circuitry.
The second terminal of the monitor should be grounding well,
接①、③位输入线必须并联接入被监测线路。
or else our company service guarantee will be nullity impotence
w
变送器②位必须有良好的接地关系,否则我公司保修承 nullification
诺无效。 Operating environment should not have the electric dust and gas
使用环境应无导电尘埃和无腐蚀金属和破坏绝缘的气 of corrosive metal and destruction insulation existence, the
altitude should less than 2,500 meters.
体存在,海拔高度小于2500米。
Suggests the user adds the 0.5A fuse in the terminal of power
建议用户在电源回路串接0.5A保险。
supply return circuit.
上海涌纬自控成套设备有限公司
电话:021-52807113/56989855
传真:021-52807115
地址:上海市大渡河路1142弄1号
邮编:200333
网址:Http://www.tkyb.com
断线监测器
Line break monitor
概述 Summarization
The line break monitor is an instrument that detect whether has
断线监测器是监测室外长距离线路是否断线的设备,具 n
outdoor long distance circuitry broken line, has the function of broken
有断线报警及继电器干接点输出功能。 line warning and the relay main contact output.
c
型号 S3-KL-J Model S3-KL-J
Capability indexes .
性能指标
h
Line break indication: when line break occur, the warning
断线指示:当发生断线时,报警指示灯亮,继电器接点
indicator light will light, the relay contact closed.
闭合。
Relay input: normallys open contact,
继电器输出:常开接点,接点容量:DC30V,1A
contact capacity: DC30V, 1A
工作电源:DC24V
Working power. supply: DC24V
整机功耗:<40mA(DC 24V时)
Full poweri supply consumption: <40mA (when DC 24V)
工频耐压:输入/输出、电源/输入之间隔离电压不小于
Power efrequency withstands voltage: the isolation voltage
2KV/1min · 1mA,电源/输出间之间隔离电压
between input/output, power/input no less than 2KV/1min · 1mA,
不小于1KV/1min · 1mA。
wthe isolation voltage between power/output no less than
监测灵敏度:6kΩ
1KV/1min · 1mA.
线路耦合电容:≤0.1uF
Monitor sensitivity: 6kΩ
安装方式: 35mm导轨和盘面镙钉固定两种方式
g Circuitry coupling capacitance: ≤0.1uF
外形尺寸:55mm×75mm×120 mm
Installation mode: 35mm guide apparatus and panel
接线图
n screw fixation
External dimensions: 55mm×75mm×120 mm
INPUT
o Wiring diagram
1 2 3 4
(As left figure shows)
y
5 6 7 8 Special hint: In order to insure the
equipment safety, the second terminal of the
.+ -
OUTP wUT 24V monitor should be grounding well.
Notice
特别提示:为确保设备安全,断
线监测器②号端子必须良好接地。 The input line which connects ① and ③ position must be
w
注意事项 parallel connection into monitored circuitry.
The second terminal of the monitor should be grounding well,
接①、③位输入线必须并联接入被监测线路。
or else our company service guarantee will be nullity impotence
w
变送器②位必须有良好的接地关系,否则我公司保修承 nullification
诺无效。 Operating environment should not have the electric dust and gas
使用环境应无导电尘埃和无腐蚀金属和破坏绝缘的气 of corrosive metal and destruction insulation existence, the
altitude should less than 2,500 meters.
体存在,海拔高度小于2500米。
Suggests the user adds the 0.5A fuse in the terminal of power
建议用户在电源回路串接0.5A保险。
supply return circuit.
上海涌纬自控成套设备有限公司
电话:021-52807113/56989855
传真:021-52807115
地址:上海市大渡河路1142弄1号
邮编:200333
网址:Http://www.tkyb.com
AIGC尊敬的用户,断线检测器是一种专门用于电力系统中电线或电缆线路运行状态监测的设备。它通过内置的传感器和电路设计,能够实时检测线路是否出现开路(即俗称的"断线")、短路或其他故障情况。简易说明书通常会包含以下内容:
1. **产品介绍**:
- 断线检测器的工作原理:一般采用电磁感应、电流监测或者声光报警等方式,当线路中断时,引发信号变化,从而触发警报。
2. **安装步骤**:
- 确认检测器适用的电压等级和线路类型
- 安装位置:选择靠近可能断线点的位置,如电缆终端头、接头处或是线路转弯、分支等高风险区域
- 接线连接:将检测器按照说明正确接入待测线路
3. **操作指南**:
- 启动电源:打开设备开关或设置相应的电源模式
- 监视显示:查看指示灯或显示屏的状态变化,正常情况下无异常;一旦出现断线或其他故障,会显示出警告信息
4. **使用注意事项**:
- 避免在潮湿、高温或有强磁场干扰的环境中使用
- 定期进行设备维护检查,确保其性能稳定
- 如遇不明信号或持续警报,请立即停止使用并查找原因
5. **常见问题解答**:
- 如何判断线路是否断开?依据设备提供的反馈信号判断,具体参照设备手册中的故障代码对照表。
总之,断线检测器简易说明书会详细介绍如何正确选购、安装及使用这种设备,帮助您有效预防和快速发现电力线路的故障情况。如有更详细的问题或需要进一步的操作指导,请随时联系我们以获取专业的技术支持。